Mitsubishi D700 Manual: A Comprehensive Guide
Mitsubishi’s FR-D700 series inverter manual provides detailed instructions for installation, operation, and troubleshooting, alongside access to MELFANS Web service.
Mitsubishi Electric’s FR-D700 series represents a robust and versatile line of frequency inverters designed for a wide spectrum of industrial automation applications. This series, detailed within the comprehensive instruction manual, offers advanced control capabilities and exceptional performance. The FR-D700 inverters are engineered to optimize motor control, enhance energy efficiency, and improve overall system reliability.
Available in various models like the FR-D720S, these inverters cater to diverse needs, from simple speed control to complex process management. Accessing resources like MELFANS Web, Mitsubishi’s FA network service, provides supplementary information and support. Understanding the core functionalities outlined in the manual is crucial for successful implementation and long-term operation.
Understanding the FR-D700 Inverter
The FR-D700 inverter, thoroughly documented in its instruction manual, functions as a sophisticated motor speed controller. It precisely regulates the frequency and voltage supplied to the motor, enabling precise speed and torque control. This inverter boasts a user-friendly interface and customizable parameters, allowing for tailored operation to specific application requirements.
Key features include built-in protection functions, ensuring both motor and inverter longevity. The manual details various control modes, including V/f control and vector control, offering flexibility in performance optimization. Utilizing MELFANS Web, Mitsubishi’s online service, provides access to detailed technical specifications and application notes for deeper understanding.

Installation and Wiring
Proper installation, guided by the manual, involves unpacking, mounting, and careful wiring according to the diagram, ensuring safe and reliable operation.
Unpacking and Inspection
Upon receiving your FR-D700 series inverter, carefully inspect the packaging for any signs of damage incurred during shipment. Once opened, verify that all components listed in the manual are present, including the inverter itself, any optional accessories, and documentation.
Thoroughly examine the inverter for any visible defects, such as cracks, dents, or loose parts. Check the rating plate to confirm it matches your order specifications. If any damage or discrepancies are found, immediately contact Mitsubishi Electric or your distributor.
Do not attempt to operate a damaged inverter. Retain the original packaging for potential returns or warranty claims, as specified within the manual’s guidelines.
Mounting the FR-D700
Proper mounting is crucial for optimal FR-D700 performance and longevity. Select a clean, dry, and well-ventilated location, free from excessive dust, humidity, and direct sunlight. Ensure the mounting surface is capable of supporting the inverter’s weight.
The manual details specific mounting orientations and required clearances for adequate heat dissipation. Securely fasten the inverter using appropriate screws, adhering to the specified torque values.
Avoid mounting near sources of strong electromagnetic interference. Proper grounding is essential; connect the inverter’s grounding terminal to a reliable earth ground, as outlined in the manual, to prevent electrical hazards and ensure stable operation.
Wiring Diagram Overview
The FR-D700 manual provides comprehensive wiring diagrams illustrating connections for power supply, motor, control signals, and protective devices. Carefully review these diagrams before commencing any wiring work. Diagrams detail proper phase sequence and grounding requirements for safe and reliable operation.
Pay close attention to the specified wire sizes and terminal connections. Incorrect wiring can lead to inverter malfunction or damage. The manual clarifies the function of each terminal, including input/output signals and control circuit connections.
Always disconnect power before making any wiring changes and verify all connections before energizing the system, referencing the detailed diagrams within the manual.
Input and Output Signal Connections
The FR-D700 manual details various input and output signal connections for flexible control and monitoring. Input signals include start/stop, forward/reverse, speed reference, and emergency stop. Output signals provide status information like running, fault, and frequency output.
The manual specifies the voltage levels and wiring configurations for each signal, including options for sinking or sourcing logic. Proper connection of these signals is crucial for correct inverter operation and integration with external control systems.
Refer to the manual’s diagrams for precise terminal assignments and ensure compatibility with your control devices, guaranteeing seamless communication.

Parameters and Settings
The Mitsubishi FR-D700 manual explains parameter groups for configuring motor, frequency, acceleration, and control settings for optimal performance.
Parameter Group Overview
The FR-D700 inverter’s parameters are logically organized into distinct groups within the comprehensive Mitsubishi manual. These groupings facilitate efficient navigation and modification of settings. Key groups include those dedicated to motor parameters – defining the motor’s characteristics for precise control. Frequency settings dictate the output frequency, influencing motor speed, while control mode parameters determine how the inverter responds to external signals.
Acceleration and deceleration time settings allow for smooth starting and stopping, minimizing mechanical stress. Further groups manage protection functions, communication protocols, and advanced features like PID control. Understanding this structure, as detailed in the manual, is crucial for tailoring the inverter’s operation to specific application requirements and ensuring optimal system performance.
Motor Parameters Configuration
Accurate motor parameter configuration is vital for the FR-D700’s optimal performance, as detailed in the Mitsubishi manual. This involves setting parameters like motor voltage, current, frequency, and poles. Correctly inputting the motor’s rated values ensures the inverter delivers the appropriate power and control signals. The manual emphasizes the importance of matching these parameters to the motor’s nameplate data.
Incorrect settings can lead to reduced performance, overheating, or even motor damage. Auto-tuning functions, described within the manual, can assist in identifying optimal parameters. Precise configuration allows for efficient motor operation, maximizing energy savings and extending the motor’s lifespan, ultimately enhancing the overall system reliability.
Frequency Setting and Control Modes
The FR-D700 Mitsubishi inverter, as outlined in its manual, offers versatile frequency setting and control modes. Users can adjust the output frequency to control motor speed, utilizing methods like potentiometer input, analog signal, or digital communication. The manual details various control modes, including V/f control for general applications and vector control for enhanced performance and dynamic response.
Selecting the appropriate control mode depends on the application’s requirements. Vector control provides superior torque control and speed accuracy, while V/f control is simpler to configure. The manual provides guidance on choosing the optimal settings for specific loads and operating conditions, ensuring efficient and precise motor control.
Acceleration and Deceleration Time Settings
The Mitsubishi FR-D700 inverter manual emphasizes the importance of properly configuring acceleration and deceleration times. These parameters, adjustable within the inverter’s settings, control how quickly the motor ramps up to the set speed and slows down. Correct settings minimize mechanical stress on the motor and driven equipment, preventing damage and extending service life.
The manual details how to set these times in seconds, considering the load inertia and application demands. Shorter times offer faster response, while longer times provide smoother operation; Improper settings can lead to overcurrent trips or unstable operation; therefore, careful adjustment based on the manual’s guidance is crucial;

Operation and Monitoring
The Mitsubishi FR-D700 manual details starting, stopping procedures, and real-time monitoring of frequency and current, aiding in efficient inverter control.
Starting and Stopping the Inverter
The Mitsubishi FR-D700 manual comprehensively explains the procedures for both starting and stopping the inverter safely and effectively. It details the necessary pre-operation checks, including verifying correct wiring and parameter settings, to prevent potential damage or hazards. The manual outlines various starting methods, such as using the operator panel, external terminals, or communication commands.
Furthermore, it clarifies the different stopping modes available – free run, DC braking, and controlled stop – and their respective applications. Understanding these modes is crucial for optimizing process control and ensuring smooth deceleration. The guide emphasizes the importance of allowing the inverter to fully stop before disconnecting power, and provides troubleshooting tips for situations where the inverter fails to start or stop as expected.

Monitoring Frequency and Current
The Mitsubishi FR-D700 manual dedicates significant attention to monitoring key parameters like frequency and current, vital for optimal performance and preventative maintenance. It details how to access real-time data via the operator panel, displaying both output frequency and motor current. The manual explains interpreting these values to assess load conditions and identify potential issues, such as overload or mechanical faults.
Furthermore, it outlines methods for utilizing external monitoring devices through analog or communication interfaces. Understanding current limits and frequency settings, as described in the manual, allows users to protect the motor and inverter from damage, ensuring prolonged operational lifespan and minimizing downtime.
Fault Detection and Troubleshooting
The Mitsubishi FR-D700 manual provides a comprehensive fault code list, crucial for efficient troubleshooting. It details common error messages, their potential causes, and recommended solutions, enabling quick diagnosis and minimizing downtime. The manual emphasizes a systematic approach, starting with verifying wiring and parameters before assuming inverter failure.
It guides users through interpreting LED indicators and error displays, offering step-by-step procedures for resolving issues. The manual also highlights safety precautions during troubleshooting, stressing the importance of disconnecting power before performing any maintenance. Accessing MELFANS Web, as the manual suggests, provides additional support and FAQs.

Advanced Features
The FR-D700 manual details advanced capabilities like PID control, Modbus communication, and multi-pump functionality, enhancing system integration and performance.
PID Control Implementation
The Mitsubishi FR-D700 inverter’s manual extensively covers PID control implementation, a crucial feature for precise process control applications. It details configuring proportional, integral, and derivative gains to optimize system responsiveness and stability. Users learn to tune PID loops for various processes, achieving accurate regulation of parameters like pressure, flow, or temperature.
The documentation explains setting up PID parameters directly through the inverter’s interface or via external signals. It also clarifies how to utilize auto-tuning functions to simplify the initial PID gain selection. Furthermore, the manual provides guidance on monitoring PID output and adjusting parameters for optimal performance, ensuring efficient and reliable control within industrial automation systems. Proper PID implementation maximizes the FR-D700’s capabilities.
Communication Protocols (Modbus, etc.)
The Mitsubishi FR-D700 inverter manual thoroughly details its communication capabilities, supporting protocols like Modbus RTU and Modbus TCP/IP for seamless integration into larger automation systems. It provides comprehensive information on register maps, data formats, and communication settings, enabling effective data exchange with PLCs, HMIs, and other devices.
The documentation explains configuring communication parameters, establishing network connections, and troubleshooting potential issues. It also covers utilizing optional communication cards to expand connectivity options. Users can leverage these protocols for remote monitoring, control, and data logging, enhancing system efficiency and diagnostics. The manual ensures users can effectively implement communication for advanced control strategies.
Multi-Pump Control Functionality
The Mitsubishi FR-D700 inverter manual outlines its advanced multi-pump control features, designed for applications requiring efficient pump management. This functionality allows for coordinated control of multiple pumps, optimizing energy consumption and ensuring reliable operation. The documentation details parameter settings for alternating lead pumps, duty/standby configurations, and flow control strategies.
It explains how to implement features like pump switching based on flow demand, preventing pump cavitation, and extending pump lifespan. Users can configure parameters to optimize pump performance based on specific application requirements. The manual provides clear instructions for setting up and troubleshooting multi-pump systems, maximizing efficiency and minimizing downtime.

Maintenance and Troubleshooting
The Mitsubishi FR-D700 manual details regular maintenance, common fault codes with solutions, and step-by-step troubleshooting for specific issues encountered.
Regular Maintenance Procedures
To ensure optimal performance and longevity of your Mitsubishi FR-D700 inverter, consistent maintenance is crucial. The manual emphasizes periodic inspections of wiring connections, verifying tightness to prevent potential hazards and operational failures. Dust accumulation should be removed regularly using compressed air – always disconnect power first!
Check the cooling fan for proper operation; any unusual noises or reduced airflow indicate a potential issue requiring attention. Inspect the inverter’s internal components for signs of overheating or damage. Routine checks of the braking resistor are also recommended, ensuring it’s free from debris and functioning correctly. Following these procedures, as outlined in the manual, will minimize downtime and maximize the service life of your FR-D700.
Common Fault Codes and Solutions
The Mitsubishi FR-D700 manual details numerous fault codes to aid in troubleshooting. A frequent code, ‘OC,’ indicates overcurrent; check for motor faults, wiring issues, or excessive load. ‘OV’ signals overvoltage, requiring investigation of the power supply and inverter settings. ‘OL’ denotes overload, suggesting a current limit has been exceeded.
Code ‘OH’ signifies overheating – ensure adequate ventilation and check the cooling fan. The manual provides specific solutions for each code, including recommended actions and potential causes. Referencing the fault code list within the manual, alongside a systematic approach, is vital for efficient diagnosis and resolution, minimizing downtime and restoring optimal inverter service.
Troubleshooting Steps for Specific Issues
The Mitsubishi FR-D700 manual guides users through specific issue resolution. If the inverter fails to start, verify power supply, input signals, and parameter settings. For motor noise, check wiring, grounding, and motor parameters. When experiencing trips during operation, consult the fault code list within the manual for detailed diagnostics.
Addressing communication errors requires confirming protocol settings and cable connections. The manual emphasizes a step-by-step approach: isolate the problem, verify connections, review parameters, and consult the troubleshooting section. Utilizing MELFANS Web service can provide further support and access to updated troubleshooting guides for the FR-D700.

Safety Precautions
The Mitsubishi FR-D700 manual stresses electrical safety, emergency stop procedures, and general guidelines to prevent hazards during installation and maintenance.

General Safety Guidelines
Prior to working with the Mitsubishi FR-D700 inverter, thoroughly review the provided manual for crucial safety information. Always ensure the power supply is disconnected before performing any installation, wiring, or maintenance procedures. Qualified personnel should exclusively handle the inverter, adhering to all relevant electrical safety standards and regulations.
Never operate the inverter in hazardous environments without appropriate safeguards. Avoid touching energized parts and utilize proper personal protective equipment (PPE), including insulated tools and safety glasses. Regularly inspect all wiring and connections for damage or wear, and promptly address any identified issues.
The manual emphasizes the importance of understanding the inverter’s limitations and operating conditions to prevent potential hazards and ensure safe operation throughout its service life.
Electrical Safety Considerations
The Mitsubishi FR-D700 inverter operates with potentially dangerous voltages; therefore, strict adherence to electrical safety protocols is paramount. Always verify the inverter’s voltage rating matches the supply voltage before connection. Grounding the inverter correctly is essential to prevent electric shock and ensure proper operation, as detailed in the manual.
Employ appropriate circuit protection devices, such as fuses or circuit breakers, to safeguard against overcurrents and short circuits. Regularly inspect wiring for insulation damage and ensure all connections are secure.
Qualified electricians should perform all electrical work, following local and national electrical codes. Never attempt repairs or modifications while the inverter is energized, and always discharge capacitors before handling internal components. Refer to the manual for specific safety guidelines.
Emergency Stop Procedures
In emergency situations, immediately disconnect power to the Mitsubishi FR-D700 inverter to halt operation. Utilize dedicated emergency stop buttons wired directly to the inverter’s control circuit, bypassing normal control sequences, as outlined in the manual. Ensure these buttons are readily accessible and clearly labeled.
Confirm the motor has completely stopped before attempting any intervention or troubleshooting. The manual details specific fault responses and procedures for safe shutdown.
Regularly test the emergency stop functionality to verify its effectiveness. Train personnel on proper emergency procedures and the location of emergency stop devices. Prioritize safety and consult the manual for detailed instructions regarding emergency operation.

Resources and Support
Mitsubishi Electric’s MELFANS Web offers extensive FA network service, including downloadable FR-D700 manuals (PDF format) and direct support access.
Mitsubishi Electric FA Network Service (MELFANS Web)
MELFANS Web, Mitsubishi Electric’s comprehensive FA network service, serves as a vital resource for FR-D700 inverter users. This online platform provides immediate access to a wealth of information, including downloadable manuals in PDF format, ensuring users always have the latest documentation readily available. Beyond manuals, MELFANS Web offers detailed technical information, FAQs, application examples, and software updates to optimize inverter performance.
Users can also find valuable support resources, connect with other users through forums, and directly access Mitsubishi Electric’s support team for personalized assistance. The URL for MELFANS Web is readily accessible, facilitating quick and easy access to these essential resources, streamlining troubleshooting and maximizing operational efficiency for the FR-D700 series.
Downloading the Manual (PDF)
Accessing the FR-D700 inverter manual in PDF format is straightforward through Mitsubishi Electric’s MELFANS Web platform. This digital version mirrors the printed manual, offering comprehensive guidance on installation, programming, operation, and troubleshooting. Downloading the PDF allows for convenient offline access, enabling technicians and engineers to consult the documentation on-site without an internet connection.
The PDF manual is searchable, facilitating quick location of specific information, and can be easily printed for reference. Regularly checking MELFANS Web for updated versions ensures users have the most current information regarding the FR-D700 series, including revisions and new features. This ensures optimal performance and safety.
Contacting Mitsubishi Electric Support
For dedicated assistance with your FR-D700 inverter, Mitsubishi Electric provides multiple support channels. Direct contact can be initiated through their official website, locating the appropriate regional support team for prompt responses to technical inquiries. The MELFANS Web platform also offers a robust knowledge base and FAQ section, potentially resolving common issues independently.
Furthermore, Mitsubishi Electric maintains a network of authorized distributors and system integrators equipped to provide local support and expertise. When contacting support, having the inverter’s model number and serial number readily available will expedite the assistance process, ensuring efficient troubleshooting and resolution of any challenges encountered.